searchpopla.blogg.se

Oxygen not included anti entropy thermo-nullifier
Oxygen not included anti entropy thermo-nullifier




Bathrooms are especially problematic to cool this way since they typically already have pipes running in the floor and roof of the room as well as the interior. The cooling pipes can also be installed into the floor and roof of rooms instead of in the middle of them. Start by insulating your geyser and putting in some extra storage for when the geyser goes dormant. In addition you can use the water when it gets too hot and dump it into a reed fiber bed. A geyser once found should be contained to keep the cold polluted water inside and cool this can be then piped though your entire base absorbing excess heat from the base. Water and polluted water in game has a very high specific heat capacity and will absorb a large amount of heat from the surroundings without increasing too much in temperature. Just remember that a single Gas Pump can only pump 500g/s while your dupes use up 100g/s each.Ĭool Slush Geysers erupt polluted water at -10 ☌ and this can be used as an effective way to cool your base. You will need an Atmo Sensor or maybe several scattered around, interconnected with automation wires, to continuously have your base depleted of warm oxygen before letting the cold oxygen inside. This system can be automated to be your only source of oxygen to constantly keep your base cooled. The less oxygen there is in your base, the less heat there is for your cold oxygen to mitigate when you pump it inside your base. Gather it inside an insulated room with a High Pressure Gas Vent and when the time comes and your base needs to be cooled down, let your dupes use up as much of the oxygen in the base as possible before starting the pump that will take the cold oxygen inside the base. The Anti Entropy Thermo-Nullifier can also be used to cool down about two pipes of oxygen with little effort, but will struggle with more. Make an oxygen production facility, cool any produced oxygen either by Thermo Regulators or by snaking the pipe through a cold biome. If you want to cool both water and base with the same pipeline, you will want to put the water at the end of the line as to not have to water heat the hydrogen and then have the hydrogen heat the rest of your base.Ĭooling oxygen is not the best solution for cooling your base, but if implemented correctly will be an easy and still very efficient way to air-condition your base. You can cool water with cold hydrogen in just the same way as cooling the rest of your base, just snake the pipeline through your water deposit. Snake the hydrogen line through your base, radiant pipes are the best, but regular pipes may also do. Cool it with 1-3 Thermo Regulators depending of the amount of cooling you need. You will need electrolyzers or a hydrogen vent to produce the hydrogen, gathering it from pockets in the caustic biome would be too much trouble. Hydrogen is the most easily cooled gas and thus best suited for cooling your base. Up to a point this also works well with the oxygen produced by Electrolyzers, with some of their produced hydrogen powering the AETN. To cool your water or your base you can use the Anti Entropy Thermo-Nullifier and Tempshift Plates instead. These materials are not easily available until the mid-game. Thermo Aquatuners are highly efficient, but ideally need Steel and Plastic for a steam turbine. Cooling water is one of the most difficult tasks in the game.

oxygen not included anti entropy thermo-nullifier

This solution can potentially solve any main overheat issue. Methods for cooling your base Anti Entropy Thermo-Nullifier & Tempshift Plate 1.1 Anti Entropy Thermo-Nullifier & Tempshift Plate.






Oxygen not included anti entropy thermo-nullifier